Programmable laboratory DC Power Supply TPM-3005
Twintex | TW-TPM-3005
Price of goods is 210.52 €.
Weight of goods is 7 Kg.
Actual in cart 0 pcs.
36V 5A and 15V 10A
Introduction
TPM-3005 are high precision programmable DC power supply with 1 output channel, the output power is W. A remarkable feature of the TPM-3005 is high resolution 1mV/1mA. Delay Time and Auto Run facilitate automatic test in different applications. USB/RS-232 interface, SCPI command sets make remote control easier. The smart cooling fan ensures low noise. OLP, OVP, OCP, OTP and reverse polarity protections protect the TPM series and their load from unexpected conditions. High stability and high accuracy further make TPM series an ideal option for various applications requiring high resolution and accurate control.
Features
- 1CH output with 2 selectable output ranges
- High range: 0-36V/0-5A, Low range: 0-15V/0-10A
- High resolution 1mV/0.1mA
- 24-bit ADC and 16-bit DAC, high accuracy
- Over load, over voltage, over current, over temperature and reverse polarity protections
- Constant voltage (CV) and constant current (CC) operations; Auto CV and CC switch
- Back-light 122×32 LCD display for full output details
- High speed rotary dial and keypad input
- Built-in beeper alarm
- Panel lock and output ON/OFF function
- 100 sets save & recall for V&I setup
- Delay time setup (99999s) and AUTO running program for easy AUTO test
- USB or RS-232 interface for PC remote control
- Support SCPI commands, support Labview
Specifications
Constantvoltageoperation | |
Lineregulation | ≤0.01%+3mV |
Loadregulation | ≤0.01%+3mV(I≤3A);≤0.02%+5mV(I>3A) |
Ripple&Noise | ≤1mVrms(I≤3A)(5Hz~1MHz);≤2mVrms(I>3A)(5Hz~1MHz) |
Recoverytime | ≤100us(50%loadchange,minimumload0.5A) |
Constantcurrentoperation | |
Lineregulation | ≤0.2%+3mA |
Loadregulation | ≤0.2%+3mA(I≤3A);≤0.2%+5mA(I>3A) |
Ripple&Noise | ≤3mArms(I≤3A);≤6mArms(I>3A) |
Display | |
Voltmeter | 5digitsLCDdisplay |
Ammeter | 5digitsLCDdisplay |
Settingaccuracy | |
Voltage | ±(0.03%reading+10mV)(25±5℃) |
Current | ±(0.2%reading+10mA)(25±5℃) |
Readingaccuracy | |
Voltage | ±(0.02%reading+5mV)(25±5℃) |
Current | ±(0.02%reading+5mA)(25±5℃) |
Protection | Overload,overvoltage,overcurrent,overtemperatureandreversepolarityprotections |
Panellock | Provided |
Programminginterface | USBorRS-232,supportSCPIcommands,supportLabview |
Memory | 100sets |
Insulation | Betweenbaseandoutputterminal≥20MΩ/500VDC |
Betweenbaseandpowercord≥30MΩ/500VDC | |
Operatingenvironment | 0℃~40℃,≤80%RH |
Storageenvironment | -10℃~70℃,≤70%RH |
Powersource | AC110V/220V±10%selectable,50/60Hz |
Accessories | Powercord×1,Operationmanual×1,Testlead×1,USBorRS-232cable×1,SoftwareCD×1 |
Dimension | 126×143×296mm |