Victron Cyrix-ct 12/24V-120A

The Cyrix Battery Interconnector is a microprocessor controlled power relay that automatically connects the batteries in parallel when one of them has reached a preset voltage (indicating that the battery is charging) and disconnects the battery when the voltage drops below the holding level (float ) voltage (indicates that one or more batteries are dead). Cyrix battery jumpers are a good replacement for Argo Diod isolators. Their main advantage is that they show practically no voltage drop, and therefore the output voltage of charging alternators or battery chargers does not need to be increased.

The standard Cyrix-ct (CT version) is intended for systems with lead-acid batteries

The Cyrix-ct intelligent battery interconnector controls the charging and disconnection of the starting and service batteries. If one of the batteries reaches 13.0 V (26 V) for 10 minutes or 13.8 V (27.6 V) for 4 seconds, the Cyrix-ct will connect the batteries and charge both batteries simultaneously to full charged state. When one of the batteries drops below 12.8 V (25.6 V) for 10 minutes or 11.8 V (23.6 V) for 4 seconds, the batteries disconnect from each other. This linking and unlinking works both ways. Batteries can be of different capacities, types and designs. Each battery is assumed to power its own appliances.

The Cyrix-ct model is equipped with thermal protection (e.g. due to prolonged overload or high ambient temperature). Cyrix switches off in case of excessive contact temperature and turns on again after cooling down.

Parallel connection in case of emergency (Start Assist)

The Cyrix can also be plugged in using a button (the Cyrix will stay plugged in for 30 seconds) or a switch to connect the batteries manually (parallel). This is especially useful in an emergency when the starter battery is dead or damaged.

System voltage: 12/24 V (auto detection

Permanent/continuous current: 120 A

Rated starting current (5 seconds): 180 A

Connection voltage: from 13 V to 13.8 V & from 26 to 27.6 V with intelligent trend detection

Cut-off voltage: from 11 V to 12.8 V & from 22 to 25.7 V with intelligent trend detection

Type of connection: 13 mm screw (M6)

Coverage (protection category): IP54

Weight: 0.11 kg

Dimensions: 80 x 46 x 46 mm

Properties

NameValue
Input voltage [V]12/24
Weight, brutto [kg]0,11
Dimension [mm]80 × 46 × 46 mm
Maximum input current [A]120
Degree of coverageIP54
ConnectorM6