ropere
0

Victron SmartSolar 150 45 MPPT solar controller

VICTRON | SCC115045212 | 8719076053026

On stock 2 pcs.

Price of goods is 203.32 €.

Weight of goods is 1.764 Kg.

Actual in cart 0 pcs.

Product was added to your cart.

Victron SmartSolar 150/45 MPPT

Robust and fast MPPT controller for demanding conditions with panel voltage up to 150 V, maximum charging current 45 A. Battery 12/24/48 V, PV max. 650/1300/2600 Wp. Built-in Bluetooth and VE.direct interface.

Ultra-fast Maximum Power Point Tracking (MPPT)

Victron Energy's MPPT solar controllers are among the absolute world leaders in this field and offer ultra-fast MPPT tracking. Especially under cloudy skies with continuously changing light intensity, thanks to this controller, solar gains are 30% higher compared to classic PWM controllers or 10% higher compared to slow MPPT controllers. Excellent efficiency up to 98%, without unnecessary energy losses with quiet passive cooling without a fan.

The maximum allowed panel power for 12 V systems is 650 Wp, for 24 V systems 1300 Wp and for 48 V systems 2600 Wp. If these values are exceeded, the controller will automatically reduce the incoming power from the panels to acceptable values, so the excess power will not damage the controller. The solar regulator is pre-set at the factory for eight types of batteries, the selection of the appropriate type is made using a rotary switch located on the body of the regulator. The maximum open-circuit voltage (referred to as Voc) of the connected solar panels must not exceed 150 V. Caution! As the outside temperature drops, the voltage of the solar panels increases. The maximum input short-circuit current of PV panels must not exceed 50 A, otherwise permanent damage may occur.

The new series of SmartSolar MPPT controllers offer built-in Bluetooth

This new feature brings the ability to connect your "smart" phone/tablet to your "smart" solar controller. You can monitor many system parameters and historical statistics for the last 30 days. You also have the option to set operating parameters. Download the free VictronConnect mobile app for iOS or Android. If you want to do the above using a PC, then you can use the VE.direct to USB cable to connect the controller and PC. You just install the Victron Connect program on your computer.

The internal electronic components are protected by a resin coating against adverse effects and for a long life. It thus offers increased protection resistance IP43 for electronic components and IP22 for connection connectors. Designed for a vertical position on a non-flammable base, with wiring from below. The regulator contains an internal temperature sensor for corresponding adjustment of the charging voltage. Automatic detection of system voltage 12/24/48 V.

Adaptive three-stage charging

  1. fast charging (Bulk), 2 . absorption (Absorption) and 3. maintenance (Float). Initially, in fast charging, a high current and lower voltage is generated to quickly recharge a discharged battery. This phase is followed by a constant voltage with decreasing current to fully charge the battery without dangerous overcharging that reduces battery life. A charged battery is kept charged by very low current and low voltage. If the battery voltage drops below 13.2 V, for example due to load, a new charging cycle is started

The voltage from the panels must exceed the battery voltage by 5V for the regulator to start working and charging the battery. The regulator charges until the voltage from the panels is 1 V higher than the battery voltage. For a 12 V battery, we recommend panels with a minimum number of 32 cells and a maximum number of 108 cells (panels in series). It is therefore possible to charge a 12 V battery as well as panels with a working voltage of 24 V. For 24 V systems, we recommend panels with a minimum number of 72 cells and a maximum number of 108 cells. The purpose is to achieve sufficient voltage to effectively and fully charge the battery.

This more powerful series of solar controllers is not equipped with a DC output. To connect a DC load to the battery, we recommend using "BP Battery Protection" with a maximum load current of up to 220 A.

Warning

  • Victron Energy MPPT controllers are not allowed to be used in combination with photovoltaic panel optimizers. MPPT controllers and optimizers may be damaged during use
  • and this damage may not be recognized as a valid claim.

Battery voltage: 12/24/48 V auto detection (36 V manual - software

Maximum battery current: 45 A

Maximum PV power, 12 V: 650 W

Maximum PV output, 24 V: 1300 W

Maximum PV output, 36 V: 1950 W

Maximum PV power, 48 V: 2600 W

Maximum PV voltage (open circuit)

  • 150 V absolute maximum in the coldest conditions
  • 145 V inrush and operating maximum

Max. short-circuit current: 50 A

Efficiency (max.): 98%

Weight: 1.25 kg

Dimensions: 186 x 130 x 70 mm

Properties

NameValue
Weight, brutto [kg]1,25
Minimum operating temperature [°C]-30
Maximum performance [W]2600
Max. output current [A]45
TechnologyMPPT